Page 5
A6 Black/Yellow, Aux 2 Output (-) 500mA. This output can be programmed to trigger when
remote button 5 is pressed followed by button 4. The output will trigger while the button is
held/ for a period of time/ or latch on/off depending on the selection made in programming
Branch 17.
A5 Blue/White, K9Funtion On/Off Status LED (-12v) Output. This wire connects to the
negative side (Gray wire) of the Status LED located in the combo LED/Pushbutton harness.
The Black wire which runs along side the Gray wire on the combo harness is the positive
wire for the LED. The positive side must be connected to a positive batter y constant source.
Note, there is a 1.5K resister inline on this wire to lower the voltage to the LED See Fig be-
low.
A4 Blue/Yellow, Glow Plug (-/+) Input. This wire connects to the wait to start indicator lamp
output on a diesel powered vehicle. This input is selectable between positive or negative sens-
ing. The factory default is set to negative. The settings are changed by changing jumper set-
tings on the board and in Program Branch 33. Note, the polarity can be changed between
negative and positive depending on the jumper setting. See Fig J1 on page 9.
A3 Blue, Trunk Trigger Input (-). This wire connects to a trunk trigger input, such as a pin
switch, to detect forced entry and trigger the alarm function.
A2 Blue/Black, K9Function On/Off & Alert Delay Input (-). This wire connects to the first
black wire of the push button switch located in the combo LED/Pushbutton harness. The
second Black wire which runs along side the first black wire on the combo harness is the
negative input wire for the switch. The negative side must be connected to a chassis ground
constant source. See Fig below
A1-A8 Wire Connections Described, Continued
Combo LED/Switch
Page 5
Battery Positive
A5 Blue/White
A2 Blue/Black
Chassis Ground
Содержание K9Caller