PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL
35
boiler)
If after 15 mins, it does
not work, there must be
wrong
degrees on the venting pipe.
No power in stove or in the
control panel.
Or Unplugged on the mother
board
The low temperature sensor
is broken
Check the power and wires.
Plug it
Replace it
3. No feeding after 20 seconds of starting.
There are three stages for the feeding process.
One is during the several minutes, feeding is constantly. "Feeding" is showing on the LCD display
Two is the following couple minutes, the feeding light is off.:"LightIing" showing on the Display
The last stage is that feeding Every several seconds all the time after previous stages.
A. For the first stage
(during first several
minutes)
Feed unit is blocked.
Check the auger is blocked or not.
There is the problem
about the connection
between motor and auger
Check the fasten screw between auger and motor loose or not.
Or the auger might jump out
No fuel in the hopper.
Fill the fuel into the hopper.
B. For the second stage
It is normal
Please be patient
C. Regarding to the last
stage
Feed unit is blocked.
Check the auger is blocked or not.
There is the problem
about the connection
between motor and auger
Check the fasten screw between auger and motor loose or not.
Or the auger might jump out
No fuel in the hopper.
Fill the fuel into the hopper.
4. Feeding not properly
A. too much wood pellet
and cannot burned in time
The level of feeding
speed is too high
Adjust the combustion fan's speed up