PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL
11
2.10. HYDRAULIC CONNECTION
IMPORTANT!
The connection of the stove to the hydraulic system must be made ONLY by qualified personnel and
can perform the installation in “ART” and in compliance with all statutory and regulatory provisions in force
and not in the country of installation. If the installation of the stove requires interaction with another existing
facility complete with another heater (gas boiler, gas boiler, oil boiler, etc ...), is recommended for more
qualified personnel who can then be challenged to answer the Full compliance of the system, per the
applicable law, and issuing the certificate. K-Stove disclaims any liability for damage to persons or property or
in the event of failure or improper operation, if not complied with the above warnings, and issued the
necessary certificates of compliance enforcement work in an appropriate manner. It is absolutely necessary
that the network is designed properly sized to dispose of all the heat flux produced by the stove to avoid
raising the temperature inside the boiler.
3. INSTALLATION AND ASSEMBLY 3.1. DRAWINGS AND SPECIFICATIONS
3.1.1. Dimensions of Hydro stoves
3.1.2. Technical data sheets
Model
KS 8020HY
SAPHIRE
Rating Voltage and Frequency
V/HZ
230V/50HZ
Maximum water pressure
Bar
1.5
Electronic consumption MAX
W/H
80
CO emission at 13%
oxygen(mg/m3) Max
18
CO emission at 13% oxygen(mg)
Min
Efficiency Max
%
90.5
Efficiency Min
%
93.9
Heat Area
M3
495
Rating power Max/Min
KW
20.6/6.5
Rating power(water) Max/Min
KW
19.06/10.6
Thermal power to the environment
Max/Min
KW
4/3.6
ΦPellet
MM
6
Length of pellet
MM
30
Hopper capacity
KG
32
Automatic burning time Max/Min
H
7.5/22
Weight
KG
185
Size(WxHxD)
MM
630*1278*72
0
ΦAir outlet pipe
MM
80
Temperature of the smoke output
Max/Min
°C
95.8/80
Flue draught pressure
Pa
0.1-15