PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL
29
4.) Safety
POWER FAILURE
After the power failure, the display will show
E7
. If you have a short cut of power failure, you manually go back to
"Stabilization" by clearing the E7 with the "okay button"
restart the stove and then keep pressing 3 seconds on the
"fire button"
On power failure a small amount of smoke may be emitted. This does not last for more than three to five minutes and
does not represent a safety risks.
POWER INPUT SOCKET
(contains the main fuse)
ELECTRIC EXCESS-CURRENT SHUT OFF
The device is protected against excess current by a main fuse (on the rear of the stove),
The following is a list of main components and their functions
IGNITER :
The STOVE comes equipped with an automatic igniter for lighting the fuel when the stove is in feeding and
lighting mode.
VACCUM SWITCH:
The STOVE has a vacuum switch located behind the left door, fastened to the base. If a low
pressure is created in the firebox by a leak, opening the front door, a blocked flue, or unsealed ash drawer (some model), the
vacuum switch will sense it and cause the stove to go into a shutdown mode by showing E5.
AUGER AND AUGER MOTOR:
The 2.4 RPM auger motor turns the auger, lifting pellets up the auger tube. The pellets
are then dropped down a tube and into the firepot. The auger motor is controlled by the control board.
PROTECT TEMPERATURE SENSOR TO AVOID
OVERHEATING.
A safety temperature switch switches the stove off automatically if it overheats,. After the stove has cooled down
meanwhile it shows E6. Whether the heating operation is continued or not depends on the remaining embers in the
fire pan. After you remove the Error Code by "Okay button" , If re-ignition does not occur when the fuel supply
recommences, then the out of operation program (cleaning , lag phase) is carried out. According to the pre-set mode
the stove must be re-started.
CAUTION: If overheating has occurred then maintenance or cleaning work must be carried out
EXHUAST TEMPERATURE SENSOR DOES FUNCTION AS
LOW TEMPERATURE SWITCH OFF