PELLET BURNING STOVES INSTALLATION & MAINTENANCE MANUAL
7
If the fuel is poor , the more often cleaning inside the grate and the combustion chamber will be
required .
K-Stove strongly recommends using certified fuel in its stoves (EN-A1 Plus).
The use of fuel of inferior quality or not conforming to the specification given above compromises the
running of your stove and can therefore lead to the termination of the guarantee and of the manufacturer's
responsibility for the product.
K-Stove pellet stoves run exclusively on pellets with a diameter of 6 mm (European countries) with lengths.
IMPORTANT!
Installation and assembly of the stove must be carried out by qualified personnel.
The stove must be installed in a suitable position to allow the normal operations of opening and ordinary maintenance.
The site must be:
capable of providing the environmental conditions for operation
equipped with power supply 230V 50 Hz
capable of taking an adequate system for smoke discharge
provided with external ventilation
provided with an earth connection complying with CEI
The stove must be connected to a flue pipe or an internal or external vertical duct conforming to current
standards UNI 7129 - 7131 9615. The stove must be positioned in such a way that the electrical plug is
accessible.
IMPORTANT!
The stove must be connected to a flue pipe or a vertical duct which can discharge the fumes at the
highest point of the building. The fumes are however derived from the combustion of wood products, and if
they come into contact with or close to walls, they can make dirty marks. Also take care because the fumes
are very hot but almost invisible, and can cause burns on contact. The holes for the passage of the smoke
pipe and for the intake of air from outside should be made before positioning the stove unit.
2.3. OPERATING ENVIRONMENT
For proper operation, and a uniform distribution of temperature, the stove
should be placed in a location with an air flow that guarantees the air
needed for combustion of the pellets (should be available approximately 40
m³ / h) according to the installation and the second regulations in the
country.
The volume of the environment must not be less than 30 m³.
The air must enter through permanent openings on the walls (near the stove) with
a minimum of 100 square centimeters.
These openings must be made so that they cannot be obstructed in any way, and
allow proper airflow. Air can also be taken to ventilate rooms adjacent provided
they are equipped with air hose and are not used as a bedroom and bathroom, or