3.3.3
Mechanical installation
The network cables must be connected to the two M12 connectors (marked "L/A IN"
and "L/A OUT") on the module. (Corresponds to CN2 and CN3 at the MIS/MIL motors).
The cable from the EtherCAT® master is always connected to the "L/A IN" port. In the
line topology, if there are more slave devices in the same line, the next slave device is
connected to the port marked "L/A OUT". If there is a redundant ring, the right "L/A
OUT" port of the last slave device is connected to the second port of the EtherCAT®
master. See the figure below. Standard CAT 5 FTP or STP cables can be used. It is not
recommended to use UTP cables in industrial environments, which is typically very noisy.
3.3.4
Synchronization configuration
The MAC00-ECx and the MIS/MIL motors supports two different synchronization
modes for their process data sync managers. These modes are:
• Free run
- No synchronization.
(Requires motor cycle to be 1.0 or 1.3ms.)
• Synchron with Sync0 Event
- Use Distributed Clock, and synchronize to Sync0.
Selection of synchronization mode is in TwinCAT done by selecting the drive and then
the DC tab, and there select the appropriate "Operation mode". Please see illustration
below.
The "Synchron with Sync0 Event" mode is only accessible in the MIS/MIL and in the
MAC00-ECx if mounted in a motor. The MAC050-141 only supports the
"Free run" mode.
EtherCAT
master
Drive
with
EtherCAT
module
Drive
with
EtherCAT
module
Drive
with
EtherCAT
module
L/A OUT
L/A IN
L/A OUT
L/A IN
L/A OUT
L/A IN
OUT
IN
TT3007GB
TT3093-01GB
Содержание MAC00-EC4
Страница 2: ......
Страница 7: ...JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors 7 1 Introduction ...
Страница 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Страница 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 33: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 33 3 EtherCAT Users Guide ...
Страница 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 79: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 79 4 EthernetIP Users Guide ...
Страница 113: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 113 5 POWERLINK Users Guide ...
Страница 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 137: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 137 6 PROFINET Users Guide ...
Страница 159: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 159 7 ModbusTCP IP Users Guide ...
Страница 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Страница 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 225: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 225 9 Module Registers ...
Страница 239: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 239 10 Using MacTalk over Ethernet ...
Страница 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Страница 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 253: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 253 11 Examples common to all protocols ...
Страница 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Страница 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...