46
IN 2
100BASE-TX
OPEN
VIDEO
LOOP
THRU
SERIAL 1
SERVICE
CONTROL
SERIAL 2
OUT
VIDEO
IN 1
OPEN
LOOP
THRU
VIDEO
RESERVED
AC IN
R
L
OUT
AUDIO
ALARM
RS485
RS232C
IN
Network
Network
ALC
LEVEL
Av Pk
L H
ALC
LEVEL
Av Pk
L H
Web browser can get and display JPEG images from camera mode.
Refreshing images
• Up to 3 JPEG images from the unit can be displayed per second.
• To refresh an image, press the Refresh button on the browser.
Specifying URL
Specify JPEG URL of the unit as follows:
http://IP address : port number/live.jpg
Example: http://10.0.0.1:8009/live.jpg
This value is fixed.
Value set in the “Network Setup Screen”.
(Default user name is “nc40jpeg” and default password is “dm-nc40”. The password can be changed.)
Enabling JPEG server of the unit
To enable JPEG server of the unit, set JPEG in the ENCODE PARAMETERS screen to “Video In 1” or “Video
In 2”. When “Disabled” is selected, Web browser can not get JPEG images from the unit.
(
See page 32)
Operating the Monitoring System
(Continued)