JVA ELECTRIC FENCE SYSTEMS
28
Installa
tion Pr
o
g
ramming Options
7.6.18 Relay Functions
All relays can be set to any of the available
functions (user assignable).
Relay 1 is (21x#)
Relay 2 is (22x#), etc.
The modes are explained in the table opposite.
The defaults for the Z114 are:
• Relay 1 – Siren (12V switched output)
• Relay 2 – Strobe (12V switched output)
• Relay 3 – Fence 1 (Note: Relay 3 is not
physically fitted to PCB)
• Relay 4 – Armed 1 (Note: Relay 4 is not
physically fitted to PCB)
• Relay 5 – General (Note: Relay 5 is not
physically fitted to PCB)
NOTE
: Optional extra relays can be retro-
fitted. Contact your nearest JVA service
centre for details.
Value (x) Mode
0
Fence 1
1
Fence 1 or off
2
Armed 1
3
Fence 2
4
Fence 2 or off
5
Armed 2
6
Fence Bi-Polar
7
General
8
Siren
9
Strobe
10
AC Fail
11
Low / Bad Battery
12
Tamper
13
Strobe 2
14
Gate 1 or 2
15
Siren caused by Gate
1 or 2
16
Armed in Low Power
Mode
17
Group Armed Note 3
18
Group General
Relay Function Values
Notes:
1. The siren and strobe switched 12V outputs
can be used to drive external buffer relays.
2. Group relay functions are only operable
on the group master.
7.6.17 Auto Re-arm Time (20x#)
This option sets the time which must elapse
before another alarm will sound after the first
alarm has timed out (gone completely through
its cycles without being turned off).
If an event occurs (such as a low fence voltage)
which triggers the siren, any other events which
would otherwise trigger the siren (such as a
gate alarm) will be ignored while the siren is
sounding and until after the Auto Re-arm time
has passed.
A setting of 0 will disable Auto Re-arm.
If this time is set to less than the Siren Off Time,
the Energizer may re-arm in the “Off” time and
the number of Siren Cycles will be reduced.
Value
Missed Pulses
0
0 Seconds (immediate)
1
30 Seconds
2
1 Minutes
3
2 Minutes
4
3 Minutes
5
4 Minutes
6
5 Minutes
7
6 Minutes
8
7 Minutes
9
Disabled – Do not auto
rearm
Auto Re-Arm Time Values