JVA ELECTRIC FENCE SYSTEMS
22
Installa
tion Pr
o
g
ramming Options
7.6 Programming Options in Detail
NOTE
: The bold panel in each table indicates the default value.
7.6.1 Power Level (01x#)
The power level option allows
the shocking power of the fence
to be adjusted. For example:
To change the power level to
maximum, enter the following:
0 1 9 # or 0 1 0 9 #
The keypad will beep twice to
indicate that the new setting
has been accepted. The actual
fence voltage depends on the
amount of fence wire and fence
conditions.
This setting may affect the
average power drain and
therefore backup battery time.
Note
: In Bi-Polar mode the voltage on each polarity output is +/-2.5kV to +/-4.75kV
i.e. half conventional mode voltage.
7.6.2 Low Power Level (02x#)
Same as above, but for Low Power mode.
Value (x) Voltage:
Conventional mode
Voltage:
Bi-Polar Mode
0
5.0kV
2.5kV
1
5.5kV
2.8kV
2
6.0kV
3.0kV
3
6.5kV
3.3kV
4
7.0kV
3.5kV
5
7.5kV
3.8kV
6
8.0kV
4.0kV
7
8.5kV
4.3kV
8
9.0kV
4.5kV
9
9.5kV
4.5kV
Power Level (01x#)
Value (x) Power
0
0.5%
1
1.0%
2
1.5%
3
2.0%
4
2.5%
5
3.0%
6
8.0kV
7
8.5kV
8
9.0kV
9
9.5kV
Low Power Level (02x#)