JVA ELECTRIC FENCE SYSTEMS
26
Installa
tion Pr
o
g
ramming Options
Value Function
0
None
1
Door Chime
2
Siren
3
Fence Alarm
4
Gate beeps plus Siren
Chime Mode (14x#)
Value Function
0
None
+1
+2
+4
+8
Active IR tamper circuit
+16
Stop slave on coms fail
+32
Do not send Alarm memory
Binary Options (16x#)
7.6.13 Chime Mode (14x#)
This option allows the energizer internal and
keypad beeper to be used as a door chime for the
gate switch. When set to
None
, the keypad beeper
is used to indicate correct keypad operation only.
When set to
Door Chime
mode, the beepers
will sound when the gate switch opens, even if
the energizer is disarmed. Note “Gate” must be
selected in 7.6.11
Input 2 Function
(Option 12).If
set to
Siren
, the beepers mimic the siren function.
Gate Beeps plus Siren will give 2 beeps on Gate open and 4 on close, plus continuous
for an alarm. Beeps are on Keypad only, not internal beeper.
7.6.14 Binary Options (16x#)
Each option in this table can be turned on
by adding the corresponding value.
For 1 set 16 to 01, for + 1 and +2
set 16 to 03.
+1: Not used on the Z114
+2: Not used
+4: Not used
+8: Activate IR tamper circuit. J3 changes
to inhibit tamper alarm rather than AC
fail alarm.
+16: Stop slaves on E-16 (Coms Fail) if the
communications from the group master is lost.
+32: Stops the energizer sending Alarm Memory to a PC, relay PCB or keypad. Set
this to restore “unlatched” mode on a PAE201 relay PCB.