JVA ELECTRIC FENCE SYSTEMS
21
Installa
tion Pr
o
g
ramming Options
7.5 Programming Options in Brief
See Section 7.6 for more detail.
Programming Options
Option Function
Description
01
Power Level
Sets the output voltage level
02
Low Power level
Sets the output power levels used in Low Power mode
03
Fence Alarm
Voltage
Sets the voltage threshold below which the fence alarm will
occur
05
Low Power Alarm
Level
Sets the voltage threshold below which the fence alarm will
occur in Low Power mode
06
Missed Pulse
Count
Sets the number of pulses which may be missed before the
alarm is activated
07
Battery Alarm
Voltage
Sets the battery voltage threshold below which the general
alarm will activate
08
Siren On Time
Sets the time that the siren (and keypad beeper) will stay on
after an alarm
09
Siren Off Time
The amount of time the siren will be off for after the On time
has expired
10
Siren Cycles
The number of times the siren will sound for the On
time function above. After this many cycles the siren will
automatically mute
11
Input Inversion
Closed to arm
or
Open to arm
12
Gate Input
Function
Gate Switch mode or Low Power Switch mode
13
Gate Exit Delay
Time from gate switch opening to alarm
14
Chime Mode
Allows the keypad and internal beeper function to be altered
16
Binary Options
Miscellaneous options
17
Anti-Bridging
If the voltage rises OR falls quickly by more than this setting
as a percentage of the average fence voltage the alarm will
occur
18
Binary Options 2
Miscellaneous options
20
Auto Re-arm Time
Sets the time which must elapse after an alarm has
timed out (completed the siren cycles) before the unit will
automatically re-arm, ready for the next alarm event.
21-25
Relay Options
To program the relay outputs to follow certain conditions of
the energizer, for enhanced monitoring purposes
26
Group ID
Allows the energizer to be set as a Master or slave in a
synchronized group. Not available in all markets.
Programming Options