JVA ELECTRIC FENCE SYSTEMS
19
T
ec
hnical Inf
or
ma
tion
6.3 Jumpers
Jumper
Function
Purpose
J3
Inhibit Mains fail error.
J3 is fitted to inhibit Mains fail errors if the
intention is to operate the energizer on DC only
(as in solar power systems).
J4
Factory default jumper
Off to return programmable
options to factory defaults on
power up.
If the energizer needs to be defaulted to factory
settings, remove all power (AC and battery) and
remove the J4 jumper. Reapply the mains and
the battery power. Reapply the J4 jumper and
the Energizer will be reset to default settings.
6.4 Configuring a Z114 to run in Bi-Polar mode
By default the Z114 is configured to run in standard mode. This procedure explains
how to modify the Z114 so that it will run in Bi-Polar mode.
Step 1
On the back of the Z114 PCB near the high voltage output terminals there is a link
(Pictured below) which needs to be cut. Cut the link so that it is flush with the PCB at
both points where it is soldered to prevent any arcing.
Step 2
Set Fence Mode (programming option 15)
to bipolar.
Value
Function
0
Bi-Polar
1
Conventional
Z114 Programming Option 15