![Juniper SRX550 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/juniper/srx550/srx550_hardware-manual_2032212053.webp)
Table 12: SRX550 Services Gateway Environmental Specifications (continued)
Value
Description
AC power: 4400 BTU/hour
DC power with one 645 W power supply unit: 2200 BTU/hour
DC power with two 645 W power supply units, nonredundant: 4400
BTU/hour
NOTE:
These specifications are estimates and subject to change.
Maximum thermal output
NOTE:
Install the services gateway only in restricted areas, such as dedicated equipment rooms
and equipment closets, in accordance with Articles 110–16, 110–17, and 110–18 of the National
Electrical Code, ANSI/NFPA 70.
RELATED DOCUMENTATION
SRX550 Services Gateway General Safety Guidelines and Warnings
Routine Maintenance Procedures for the SRX550 Services Gateway | 123