• Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance,
and secure it to the building structure.
• Read
General Safety Guidelines and Warnings
, with particular attention to
Ensure that you have the following parts and tools available:
• Phillips (+) screwdriver, number 2 (not provided).
• Screws to secure the chassis to the rack (not provided).
• 2-in.-recess front-mounting brackets (from the separately orderable four-post rack-mounting kit) if
you will mount the switch in a recessed position.
You can mount an EX4100 and EX4100-F switch on two posts of a 19-in. rack or cabinet by using the
front mounting brackets provided with the switch. (The remainder of this topic uses
rack to mean rack or
cabinet.)
You can mount the switch on four posts of a four-post rack by using the mounting brackets provided
with the separately orderable four-post rack-mounting kit. See
Switch on Four Posts in a Rack or Cabinet" on page 126
.
NOTE: If you need to mount the switch in a recessed position on either a two-post rack or a
four-post rack, you can use the 2-in.-recess front-mounting brackets provided in the separately
orderable four-post rack-mounting kit.
NOTE: One person must be available to lift the switch while another secures the switch to the
rack.
CAUTION: If you are mounting multiple units on a rack, mount the heaviest unit at the
bottom of the rack and mount the other units from the bottom of the rack to the top in
decreasing order of the weight of the units.
To mount the switch on two posts in a rack:
124
Содержание EX4100
Страница 1: ...EX4100 and EX4100 F Switch Hardware Guide Published 2022 11 08 ...
Страница 68: ...Figure 45 Front to Back Airflow Through the EX4100 48P or EX4100 48T Switch Chassis 59 ...
Страница 69: ...Figure 46 Front to Back Airflow Through the EX4100 24MP or EX4100 48MP Switch Chassis 60 ...
Страница 70: ...Figure 47 Front to Back Airflow Through the EX4100 F 24P Switch Chassis 61 ...
Страница 71: ...Figure 48 Front to Back Airflow Through the EX4100 F 24T Switch Chassis 62 ...
Страница 72: ...Figure 49 Front to Back Airflow Through the EX4100 F 48P Switch Chassis 63 ...
Страница 105: ...Figure 62 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 24MP and EX4100 48MP Switch 96 ...
Страница 106: ...Figure 63 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24T Switch 97 ...
Страница 107: ...Figure 64 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24P Switch 98 ...
Страница 108: ...Figure 65 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 48P Switch 99 ...
Страница 209: ...5 CHAPTER Troubleshoot Hardware Troubleshoot the EX4100 and EX4100 F Components 201 ...