shows the components on the rear panel of EX4100-F-48T switch.
Figure 35: Components on the Rear Panel of EX4100-F-48T Switch
1
—
RJ-45 management port (labeled MGMT)
6
—
CLEI code label
2
—
Protective earthing terminal
7
—
Electrostatic discharge (ESD) point
3
—
Built-in fan module
8
—
Claim Code label
4
—
Serial number
9
—
RJ-45 console port (labeled CON)
5
—
AC power supply socket
10
—
USB 2.0 Type A port
Uplink Ports
EX4100 and EX4100-F switches have autosensing uplink ports that you can use to connect an access
switch to a distribution switch. The uplink ports on the front panel are configured as network ports by
default. You cannot use the uplink ports as Virtual Chassis ports. The uplink ports on the front panel
support 1-gigabit SFP transceivers and/or 10-gigabit SFP+ transceivers. You can use a combination of
SFP and SFP+ transceivers.
For a list of supported transceivers, see
"Pluggable Transceivers and Cables Supported on EX4100 and
EX4100-F Switches" on page 101
Virtual Chassis
EX4100 and EX4100-F switches have dedicated Virtual Chassis ports (VCPs) that you can use to
interconnect member switches of a Virtual Chassis. Only homogenous virtual chassis is supported; that
is, you can connect any EX4100 switch, including EX4100 multigigabit switch and EX4100-F switch, in a
virtual chassis. You can interconnect a maximum of 10 switches to form a Virtual Chassis. You can
operate these interconnected switches as a single, logical device with a single IP address. If you operate
the interconnected switches as a single device, you must use all the Virtual Chassis ports as Virtual
Chassis ports or use all of them as network ports. You cannot mix multiple types of ports within a single,
logical device.
For more information about Virtual Chassis, see
Understanding EX Series Virtual Chassis
.
19
Содержание EX4100
Страница 1: ...EX4100 and EX4100 F Switch Hardware Guide Published 2022 11 08 ...
Страница 68: ...Figure 45 Front to Back Airflow Through the EX4100 48P or EX4100 48T Switch Chassis 59 ...
Страница 69: ...Figure 46 Front to Back Airflow Through the EX4100 24MP or EX4100 48MP Switch Chassis 60 ...
Страница 70: ...Figure 47 Front to Back Airflow Through the EX4100 F 24P Switch Chassis 61 ...
Страница 71: ...Figure 48 Front to Back Airflow Through the EX4100 F 24T Switch Chassis 62 ...
Страница 72: ...Figure 49 Front to Back Airflow Through the EX4100 F 48P Switch Chassis 63 ...
Страница 105: ...Figure 62 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 24MP and EX4100 48MP Switch 96 ...
Страница 106: ...Figure 63 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24T Switch 97 ...
Страница 107: ...Figure 64 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 24P Switch 98 ...
Страница 108: ...Figure 65 Clearance Requirements for Airflow and Hardware Maintenance for the EX4100 F 48P Switch 99 ...
Страница 209: ...5 CHAPTER Troubleshoot Hardware Troubleshoot the EX4100 and EX4100 F Components 201 ...