Operation
22/30
4156 EN
End of charge data
Voltage: 2,7 V/Z
Current: 10,5 A
Recharged Ah: 120,00 Ah
Charging
finished!
Figure 7: Alternating charge end display (RH picture: sample values)
6.7
Readings
As described in Section 6.1.4, certain readings can be displayed before, during and after
the charge. The number of readings can be set from 1 to 5. For the various charger
conditions the readings have the following significance:
Reading
Charger condition
Value displayed
Charge voltage*
Charge, conservation charge
Charge voltage
Recharge interval
Battery voltage
Charge end, conservation charge interval
Charge end voltage
Charge current*
Charge, recharge interval, conservation
charge
Charge current
Charge end, conservation charge interval
Charge end current
Charge voltage
[V/C]
Charge, conservation charge
Charge voltage [V/C]
Recharge interval
Battery voltage [V/C]
Charge end, conservation charge interval
Charge end voltage [V/C]
Charge current %
(of charge rated
current)
Charge, recharge interval, conservation
charge
Charge current [%]
Conservation charge interval
Charge end current %
Ah total*
Charge, recharge interval
Current Ah total
Charge end, conservation charge interval
Charge end Ah total
Battery
temperature
Charge, recharge interval, conservation
charge
Current temperature
Charge end, conservation charge interval
Charge end temperature
Charge time*
Charge, recharge interval, conservation
charge
Current charge time
Charge end, conservation charge interval
Overall charge time
Date
Charge, recharge interval, conservation
charge
Current date
Charge end, conservation charge interval
Charge end date
Time*
Charge, recharge interval, conservation
charge
Current time
Charge end, conservation charge interval
Charge end time
Module status
All charging phases
Decimal value, display for
charger service only
*Default values