Electrical installation (wire cross sections, fuses, earth leads) must be performed in
accordance with current regulations.
Prior to electrical installation, the performance data on the data plate must be checked
against the performance data of the supply connections. The charger must be protected
against excessive shock-hazard voltages through a mains fuse connected in series.
Observe the mains connection values indicated on the data plate (voltage and
frequency).
2.6
Operating Safety Instructions
The charger must only be used when in technically good working order and when used
in accordance with the present operating instructions with attention paid to the safety
and hazard risks. Any faults that could affect safety must be removed immediately.
The data plate specifications regarding the appropriate battery voltage must be checked
and complied with prior to connecting the charger cable. The charger leads must be
connected to the correct battery terminals.
When connecting the battery, route the charging leads so that they cannot be tripped
over and that charging cannot be interrupted by unplugging the charging lead. If an
ongoing charge is interrupted by removing the charging lead, this may produce sparks
which could result in fire or explosions.
If the charger or the operating pattern of the charger is changed in a way that could
affect safety, shut down the charger and notify the relevant department of the fault.
2.7
Troubleshooting and Repairs Safety Instructions
Contact the manufacturer prior to opening the housing for maintenance and repair
purposes.
Prior to carrying out maintenance or repair work, always disconnect the charger from the
mains.
After switching off the charger, wait for at least five minutes before opening the panels
and housing.
No changes or modifications may be made to the charger which could affect safety
without obtaining the manufacturer’s approval. This also applies to the assembly and
setting of safety mechanisms. In particular make sure that no safety, leakage or air
distances are reduced.
Spare parts used must meet the technical requirements specified by the manufacturer.
This requirement is always met by original manufacturer’s spare parts.
3
Product Specifications
3.1
Product Functional Description
The SLH 200 charger is designed to charge lead acid accumulators. Depending on the
preset charging program, wet cell batteries or sealed, maintenance-free traction batteries
can be charged.
The charger has an adjustable, high-frequency power part, a micro-processor controlled
charging electronics system and a control/display panel with buttons and a charge status
light, as well as a graphic enhanced LCD display. The charging program for the