02
.1
6
EN
18
5.2
Operation
5.2.1 Commissioning
Checks and operations to be performed before starting daily work
Procedure
• Make sure the battery is in physically good condition.
• Make sure the terminals are correct (positive to positive and negative to negative)
and check that contacts on the battery terminal conducting system are secure.
• Check the M10 terminal screws of the conductors and connectors are secure and
if necessary torque to 23 ±1 Nm.
• Charge the battery, see page 18.
The test is now complete.
5.2.2 Discharging the battery
Z
To achieve an optimum useful life avoid operational discharges of more than 60%
of nominal capacity.
Z
If the battery is discharged during operation by more than 80% of rated capacity the
useful life of the battery will reduce significantly. Fully or partially discharged
batteries must be re-charged immediately and not left unattended.
5.2.3 Charging the battery
WARNING!
The gases produced during charging can cause explosions
The battery gives off a mixture of oxygen and hydrogen (electrolytic gas) during
charging. Gassing is a chemical process. This gas mixture is highly explosive and
must not be ignited.
Always disconnect the charger and truck before connecting or disconnecting the
charger and battery.
The charger must be adapted to the battery in terms of voltage, charge capacity
and battery technology.
Before charging, check all cables and plug connections for visible signs of damage.
Ventilate the room in which the truck is being charged.
Battery cell surfaces must remain exposed during charging in order to ensure
sufficient ventilation, see truck operating instructions, chapter D, Charging the
Battery.
Do not smoke and avoid naked flames when handling batteries.
Wherever an industrial truck is parked for charging there must be no inflammable
material or consumables capable of creating sparks within a minimum distance of
2000 mm from the truck.
Fire protection equipment must be available.
Do not place any metallic objects on the battery.
Always follow the safety regulations of the battery and charger station
manufacturers.
Содержание EFX 410
Страница 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Страница 2: ...2 ...
Страница 4: ...4 04 19 en GB ...
Страница 12: ...0506 GB 2 0506 GB 2 ...
Страница 72: ...70 04 19 en GB ...
Страница 90: ...88 04 19 en GB ...
Страница 250: ...248 04 19 en GB ...
Страница 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Страница 332: ...4 Maintenance and repairs 4 1 Preparing the truck for maintenance and repairs 8 9 33 330 04 19 en GB ...
Страница 376: ......
Страница 380: ...02 16 EN 6 ...
Страница 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Страница 404: ......