4. Overloading protection 400 V/230V
IMPORTANT !
The generator is fitted with an Overloading protection 400 V/230V.
They will cut off the output when the connected device is overloaded. If it is activated, and then You can push
the lever up to reset the output.
IMPORTANT !
If this happens, reduce the electric power you are taking from the generator or remove any
defective connected appliances.
5. Overloading (Inrush Current)
You may find that even though the appliance you wish to connect to the generator is below the rated power,
the generator overloads.
Some appliances require a higher power than noted on the appliance for start up; this is called inrush current.
Some examples are listed below.
1. Air Filter Service
CAUTION: DO NOT USE THE GENERATOR WITHOUT THE AIR FILTER FITTED, THIS CAN
DAMAGE THE GENERATOR.
The air filter should be cleaned every 50 hrs of operation.
a)
Loosen the service cover screwing.
b)
Remove the cover.
c) Remove the air filter.
d)
Clean the filter with spirit or ethanol
e)
Drop a small amount of oil on the air filter and compress it.
f)
Put the filtration cartridge back and put the housing on.
WARNING: DO NOT USE INFLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER
70 W
650 W
700 W
800 W
1100 W
1200 W
2000 W
2100 W
2400 W
70 W
1300 W
2000 W
2000 W
4000 W
2100 W
2000 W
3200 W
2400 W
Appliance
Light
Airless Sprayer
Refrigerator
Water Pump
Air Compressor(1HP)
Circular Saw
Heater
Mitre Saw
Electric Stove
Running Wattage
Start-up Wattage
*
Table details are approximate. Always check your appliance for the accurate wattage.
MAINTENANCE
• Good maintenance is essential for safe, economical and trouble-free operation. It will also help reduce air
pollution.
• The purpose of the maintenance and adjustment schedule is to keep the machine in the best operating
condition.
• Turn off the engine before performing any maintenance. The exhaust contains poisonous carbon monoxide
gas. Please always select recommended accessories. The accessories which have not equivalent quality may
damage the machine.
• Please never use non-approved components and never remove the safety devices.
CAUTION!
• Always stop the engine before servicing, and disconnect all appliances to avoid receiving an electrical shock.
• Periodic checks and maintenance are very important for keeping the generator in good condition
Controllare la tensione
della batteria
Ogni volta prima di utilizzare il generatore.
Item
Machine oil check
Replace engine oil
Daily
check
Check
20 Hrs
month
1 year
Replace
50 Hrs
100 Hrs or
or every
3 months
every
6 months
Replace
300 Hrs or
every
Air filter check
Valve clearance
Cylinder cover wash
Fuel tank wash
Check
Wash if necessary, replace every 3 years
Check
Clean
Air filter wash
Check/
adjust