– 36 –
No
Item
Description
Range
Initial value
DD22
DD23
P049
Automatic suction ON / OFF
Type of operation of the automatic suction can be selected with this function setting number.
(0: OFF / 1: Front suction / 2: Rear suction /3: Front and rear suction)
0-3
3
3
P050
Front suction, continuing number of
stitches
This function setting number is used for setting the number of stitches to be sewn continuously
until the front suction stops after the intermediate sensor has detected the material.
(Unit: stitch)
0-50
5
5
P051
Intermediate suction, continuing
number of stitches
This function setting number is enabled only in the case "DD22" is selected with the function
setting number "P125 Model selection".
This function setting number is used for setting the number of stitches to be sewn continuously
until the rear suction stops after the material has passed the intermediate sensor. (Unit: stitch)
0-50
35
5
P052
Intermediate suction, starting num-
ber of stitches
This function setting number is enabled only in the case "DD22" is selected with the function
setting number "P125 Model selection".
This function setting number is used for setting the delaying number of stitches to be sewn be
-
fore the rear suction starts after the material has passed the intermediate sensor. (Unit: stitch)
0-50
0
0
P053
Rear suction, duration
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
This function setting number is used for setting the duration of suction until the rear suction is
stopped after the rear thread trimmer has started. (Unit: ms) If the rear thread trimmer is set to
"OFF", the rear suction will not operate.
0-5000
200
200
P054
Manual suction ON / OFF
It is possible to select the type of operation of manual suction to be carried out by pressing the
hand switch. (0: OFF / 1: Rear suction / 2: Front and rear suction)
0-2
1
1
P055
Manual suction, duration
This function setting number is used for setting the duration of suction until the suction (set
with P054) is stopped by pressing the hand switch. (Unit: ms)
0-2000
500
500
P056
Low pressure mode ON / OFF
If the supplied air pressure is low, set this function setting number to "ON". Then, the function
set with the function setting number P057 is enabled. (0: OFF / 1: ON)
0-1
0
0
P057
Suction synchronization time
This function setting number is enabled when "P056 Low pressure mode" is set to "ON". The
device connected to Suction 2 will operate simultaneously with the device connected to Suc-
tion 1 during the time set with this function setting number. (Unit: ms)
0-2000
200
200
P058
Continuous material feeding section
ON / OFF
It is possible to select the type of operation of the device connected to Suction 2.
(0: OFF / 1: Long suction / 2: Synchronized suction / 3: Intermittent suction (controlled by time)
/ 4: Intermittent suction (controlled by the number of stitches))
Refer to the Engineer's Manual for how to connect the device to Suction 2.
0-4
2
2
P059
Intermittent suction, time
This function setting number is enabled when P058 is set to "3: Intermittent suction (controlled
by time)". The operating time of the intermittent suction. (Unit: x100ms)
1-600
2
2
P060
Intermittent suction, duration
This function setting number is enabled when P058 is set to "3: Intermittent suction (controlled
by time)". The operating time of the intermittent suction. (Unit: x100ms)
1-600
2
2
P061
Intermittent suction, the number of
stitches
This function setting number is enabled when P058 is set to "4: Intermittent suction (controlled
by the number of stitches)". The number of stitches to be sewn while operating the intermittent
suction. (Unit: stitch)
0-200
50
50
P062
Intermittent suction, stopping num-
ber of stitches
This function setting number is enabled when P058 is set to "4: Intermittent suction (controlled
by the number of stitches)". The number of stitches to be sewn while operating the intermittent
suction. (Unit: stitch)
0-200
50
50
P066
Auto lifter ON / OFF
It is possible to select the type of operation of the auto lifter with this function setting number.
(0: OFF / 1: Front lifter / 2: Rear lifter / 3: Front and rear lifters)
0-3
0
0
Содержание MO-6800D/DD20 Series
Страница 1: ...MO 6800S D DD20 Series INSTRUCTION MANUAL...
Страница 20: ...17 MO 6814 44H MO 6816...
Страница 21: ...18 MO 6816 50H MO 6816 60H...
Страница 74: ...71 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...
Страница 76: ...73 Auxiliary table for fully sunken type table Unit mm Difference 2 Weight 4 25 kg 5...