– 34 –
No
Item
Description
Range
Initial value
DD22
DD23
P022
Intermediate sensor ON / OFF set-
ting
In the case the front sensor has failed, this function setting number should be set to "OFF".
(0: OFF / 1: ON)
0-1
1
1
P023
Rear sensor ON / OFF setting
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection". If both P022 and P023 are set to "OFF", the automatic
mode of DD23 cannot be used. (0: OFF / 1: ON)
0-1
0
0
P024
Number of stitches between both
sensors
This function setting number is used for setting the number of stitches to be sewn after one
sensor has detected the material and before the next sensor does. If the next sensor fails
to detect the material, the sewing machine will stop running after it has sewn the number of
stitches set with this function setting number. (Unit: stitch)
1-600
20
20
P025
Stop-delay number of stitches
This function setting number is enabled in the case the rear thread trimmer is set to "OFF".
The sewing machine stops after it operates by the number of stitches set with this function set
-
ting number after the material has passed the last sensor. (Unit: stitch)
0-99
0
0
P026
Free stitching ON / OFF
It is possible to select either the semi-automatic mode or the free stitching with this function
setting number.
In the case the free stitching is selected, the sewing machine will not stop running if the front
part of the pedal is held depressed after the completion of thread trimming. (0: OFF / 1: ON)
0-1
0
0
P029
Automatic thread trimming ON / OFF
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection". It is possible to select the operation of the automatic
thread trimmer with this function setting number.
(0: OFF / 1: Front thread trimmer / 2: Rear thread trimmer / 3: Front and rear thread trimmers)
0-3
3
3
P030
Automatic constant-speed thread
trimming ON / OFF
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
It is possible to select the operation of the automatic thread trimmer with this function setting
number. (0: OFF / 1: Automatic constant-speed thread trimming)
0-1
0
0
P031
Front thread trimmer, starting num-
ber of stitches
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
This function setting number is used for setting the number of stitches to be sewn until the
front thread trimmer operates after the material has passed the intermediate sensor. The
smaller this value is set, the longer the remaining thread length becomes. (Unit: stitch)
0-50
3
3
P032
Rear thread trimmer, starting num-
ber of stitches
This function setting number is enabled only in the case "DD23" is selected with the function
setting number "P125 Model selection".
This function setting number is used for setting the number of stitches to be sewn until the rear
thread trimmer operates after the material has passed the rear sensor. The smaller this value
is set, the shorter the remaining thread length becomes. (Unit: stitch)
0-50
3
3
P033
Number of stitches to prevent cloth
trimming
In the case "DD22" is selected with the function setting number "P125 Model selection" (setting
is enabled for the Service level), the sewing machine stops running or the rear thread trimmer
operates after the sewing machine has sewn the number of stitches set with this function set
-
ting number after the material has passed the intermediate sensor.
In the case "DD23" is selected with the function setting number "P125 Model selection" (setting
is enabled for the Service level), and the function setting number "P023 Rear sensor ON / OFF
setting" is set to "OFF", the sewing machine stops running or the rear thread trimmer operates
after the sewing machine has sewn the number of stitches set with this function setting number
(P033) and the number of stitches set with P032 after the material has passed the intermedi
-
ate sensor.
The number of stitches set with this function setting number should be referred to in the case
"1: Check pattern material" is selected with the function setting number "P089 Check pattern
material". (Unit: stitch)
0-50
0
8
Содержание MO-6800D/DD20 Series
Страница 1: ...MO 6800S D DD20 Series INSTRUCTION MANUAL...
Страница 20: ...17 MO 6814 44H MO 6816...
Страница 21: ...18 MO 6816 50H MO 6816 60H...
Страница 74: ...71 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...
Страница 76: ...73 Auxiliary table for fully sunken type table Unit mm Difference 2 Weight 4 25 kg 5...