– 103 –
(3) List of error code
Error
number
Description
How to correct
E001 High-voltage error (320 V or more) Turn the power OFF. Check the supply voltage.
E002 Low-voltage error (170 V or less) Turn the power OFF. Check the supply voltage.
E003 CPU communication fault
Turn the power OFF. Check the connection of the connector to
the operation panel and the cable.
E005 Pedal connection fault
Turn the power OFF. Check the connection of the connector to
the pedal and the cable.
E007 Main shaft rotation fault
Check whether the main shaft motor is locked by turning the
pulley. Check the connection encoder cable and motor power
cable to the connectors.
Check whether the supply voltage is normal. Check whether
the sewing speed is set extremely high.
E009
E011
Encoder Z-phase detection fault
Turn the power OFF. Check the connection of the motor
encoder cable to the connector.
E014 Encoder AB-phase detection fault
Turn the power OFF. Check the connection of the motor
encoder cable to the connector.
E015 Main shaft motor overcurrent error Turn the power OFF. Then, re-turn the power ON.
E017 Machine head tilting error
Raise the machine head. Then, turn the power OFF and re-turn
the power ON. Check whether the machine head tilt switch has
broken.
E020 Main shaft rotation fault
Turn the power OFF. Check the connection of the main shaft
motor encoder cable and motor power cable to the connectors.
E030
Communication fault between the
main CPU and the presser motor
CPU
Turn the power OFF. Check whether the presser motor is
locked. Check the connection of the presser motor to the
connector.
E031 Presser motor overcurrent error
Turn the power OFF. Check whether the presser motor is
locked. Check the connection of the presser motor to the
connector.
E032 Presser motor origin retrieval error
Turn the power OFF. Check whether the presser motor is
locked. Check the connection of the presser motor and origin
sensor to the connectors.
E040 Crystal oscillator fault
Turn the power OFF. Change the panel PCB with a new one.
E220 Grease shortage warning
Carry out maintenance for replenishing the grease. Then, reset
the error (to clear N15).
E221 Grease-shortage error
Carry out maintenance for replenishing the grease. Then, reset
the error (to clear N15).