Appendix B Alert, Maintenance INFO and Permanent information
B-68
Message Explanation
Advice
TXRX(DRV IPM OVH)
The temperature of IPM of
the motor driver circuit in
the radar antenna is
abnormal.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
TXRX(DRV Low Rotate)
The rotation speed of the
antenna is lower than the
specification.
Confirm that the status is standby and, if the
status is transmitting, set the status to
standby.
After that, set the status to transmitting again.
If it cannot be recovered after repeating the
above operation three times, turn off the
device and contact the distributor.
TXRX(DRV MOT OVH)
The temperature of the
motor in the radar antenna
is abnormal.
Turn off the power of the device and restart
after ten minutes.
If it cannot be recovered, turn off the device
and contact the distributor.
TXRX(DRV OVC)
The supply current of the
motor in the radar antenna
exceeds the rated value.
Confirm that the status is standby and, if the
status is transmitting, set the status to
standby.
Then, after confirming that there is no
obstruction in the swing circle of the antenna,
set the status to transmitting again.
If it cannot be recovered after the operation
above, turn off the device and contact the
distributor.
TXRX(DRV Over
Rotate)
The rotation speed of the
antenna is abnormally
higher than the
specification.
Confirm that the status is standby and, if the
status is transmitting, set the status to
standby.
After that, set the status to transmitting again.
If it cannot be recovered after repeating the
above operation three times, turn off the
device and contact the distributor.
TXRX(DRV VBUS LKV)
The supply voltage of the
motor in the radar antenna
falls short of the rated
value.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
TXRX(DRV VBUS OVV)
The supply voltage of the
motor in the radar antenna
exceeds the rated value.
Restart the power.
If it cannot be recovered after three times of
restart, turn off the device and contact the
distributor.
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......