Section 19 Adjusting and Setting up Equipment (for Services)
19-10
19.2.4.2 Adjusting a magnetron radar performance monitor
On the [Performance Monitor] dialog, adjust a magnetron radar transmitting/receiving status while
checking the performance monitor level.
Adjusting a monitor reception level
Adjust the circuit for monitoring the radar equipment reception performance.
1
Click on the [MON Adjustment] (MON reception level adjustment) input box.
A numeric value input keyboard is displayed.
2
Enter a setting value in the input box so that the farthest position of the performance
monitor pattern becomes 18.00 NM. (0 to 127)
For the method of using the numeric input keyboard, refer to "3.16.2 Name and function of each
section of the keyboard".
Performance monitor pattern
18.00 NM
Performance monitor level
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......