5
Replace the magnetron.
Remove the screws (six M4 screws)
holding the magnetron in place and
replace the magnetron.
Use a shielded secrewdriver because
the contact of the metal tool with the
magnetron causes deterioration of its
performance.
Cut the leads (yellow and green) for
the replacement magnetron to an
appropriate length, then tighten the
screws and fix the cables in place.
After having replaced the magnetron,
reassemble the unit by following the
disassembly procedure in the reverse
order.
Do not forget to tighten the bolts and
screws, and do not forget to
reconnect the cables.
Extreme care should be taken to connect the leads (yellow and green) to the magnetron
for prevention of contact with other parts or the casing. Contact may cause them to
discharge.
Nut plate
Remove
the six
screws.
Magnetron
Green cable
Yellow cable
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......