Section 19 Adjusting and Setting up Equipment (for Services)
19-14
19.2.6 Adjusting the TT function
Adjust the following TT function parameters by using the [TT] dialog.
• Vector
constant
• Quantization
level
• Target symbol display position
• Gate size used for tracking
• TT limit ring
What is quantization level?
A quantization level is a signal level that is recognized by the TT function as a target.
By setting a lower value, input of signals of weak targets in the TT target detection circuit is enabled.
However, many unnecessary signals are also input, destabilizing acquisition and tracking of targets
due to unnecessary signals. It is important to set a value greater than the value for detecting
unnecessary signals by 4 or 5.
Do not change the quantization level settings indiscreetly.
If inappropriate values are set, the acquisition of the target tracking function and
the tracking function will deteriorate, possibly causing accidents.
19.2.6.1 Displaying the [TT] dialog
When [TT] is selected in the classification pane, the [TT] dialog is displayed in the edit pane.
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......