24-43
Section 24 Specifications
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
付録
Receivable signals (i)
Ship heading
THS > HDT (over 40Hz)
Course
GGA > RMC > RMA > GNS > GLL
Geodetic positioning system
DTM
Date information
ZDA
COG/SOG
RMC > RMA > VTG
Ship speed through water
VBW > VHW
Turning speed
ROT
Water depth
DPT>DBS>DBT>DBK
Wind direction/wind speed
MWV>MWD
Air temperature
MTA > MDA
Water temperature
MTW > MDA
Atmospheric pressure
MMB > MDA
Humidity
MHU > MDA
AIS
VDM, VDO
TT data
TTM, TLL, TTD, TLB
AIS target data
TTM, TLL, TTD
Alert
ACN, HBT
NAVTEX
NRX or JRC format
Azimuth/distance to the destination
RMB > BWC > BWR (Plotter option)
Water current
CUR
Automatic sailing and Track control
(Can be received during automatic sailing or track control)
TOKIMEC : Autopilot (KELVIN)
ROT
TOKYO KEIKI : PR-6000, HCS-9000
HTD
YDK : PT500, PT900
HTD
、
ZDL
ALPHATRON : Alphapilot MFM
HTD
、
ZDL
Transmittable signals
Own ship data
OSD
Watch Timer Reset
EVE*
2
TT data
TTM, TLL, TTD, TLB
Remote maintenance data
JRC format
Alert
ALC, ALF, ARC, HBT
Route information
ECDIS information notification (PJRC,EIF00/PJRC,EIS00/WPL)
Auto pilot information
ECDIS information notification (PJRC,EIF00)
NAVTEX
NRM
Azimuth/distance to the destination
RMB, BWC
Automatic sailing and Track control
(Can be transmitted during automatic sailing or track control)
TOKIMEC : Autopilot (KELVIN)
CTS, HTR
TOKYO KEIKI : PR-6000, HCS-9000
HTC, XTE, VBW, VTG, PJRCI, HSC
YDK : PT500, PT900
HTC, XTE, VBW, VTG
ALPHATRON : Alphapilot MFM
HTC, XTE, GLL, VHW, VTG, PNEY,001, PNEY,002
Navigation Data
DBK, DPT, DTM, GGA, GLL, HDG, HDT, MDA, MWV, NSR, POS,
RMB, RMC, ROT, RSA, THS, VBW, VDR, VTG, VWR, VWT, XDR,
ZDA, HBT, BWC, RTE, WPL, HSC, OSD, RSD, XTE, ZTG
Visual range
Visual range
1.05m from the center of display
ii. The measuring precision of the speed sensor complies with IMO Resolution MSC.96(72).
The measuring precision of the GPS sensor complies with IMO Resolution MSC.112(73).
*1 e-Token (Option) is required to use C-map.
*2 When the value exceeds the set value, a message is output indicating a non-operation state. The value is set at
installation.
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......