Section 19 Adjusting and Setting up Equipment (for Services)
19-12
The type of transmission/reception attenuator value that is used as the reference for the adjustment at
the setting change varies depending on the setting item.
Setting Display
Tx Monitor Adjustment
Tx Attenuator Value is displayed.
Rx Monitor Adjustment
Rx Attenuator Value is displayed.
Monitor Sector
Rx Attenuator Value is displayed.
Monitor Range
Rx Attenuator Value is displayed.
Rx Monitor Gain
Rx Attenuator Value is displayed.
Perform the following adjustments by using the transmission/reception attenuator value as the
reference in the [Performance Monitor (SSR)] dialog.
Note
Do not change the values set in the [Monitor Range] input box and the [RX Monitor Gain]
(reception monitor gain) input box.
Adjusting a monitor transmission level
Adjust the circuit for monitoring the radar equipment transmission performance.
1
Click on the [TX Monitor Adjustment] (transmission monitor adjustment) input box.
A numeric value input keyboard is displayed.
2
Enter a setting value in the input box so that "0.0±1.0dB" is indicated as the [Reference
Attenuator Value]. (0 to 127)
For the method of using the numeric input keyboard, refer to "3.16.2 Name and function of each
section of the keyboard".
Adjusting a monitor reception level
Adjust the circuit for monitoring the radar equipment reception performance.
1
Click on the [Monitor Sector] input box.
A numeric value input keyboard is displayed.
2
Input a setting value in the input box so that the maximum value is indicated as the
[Reference of Attenuator Value].
For the method of using the numeric input keyboard, refer to "3.16.2 Name and function of each
section of the keyboard".
3
Click on the [RX Monitor Adjustment] (reception monitor adjustment) input box.
A numeric value input keyboard is displayed.
4
Enter a setting value so that "0.0±1.0dB" is indicated as the [Reference of Attenuator
Value] (0 to 127).
For the method of using the numeric input keyboard, refer to "3.16.2 Name and function of each
section of the keyboard".
Содержание JMR-7210-6X
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 230: ...Section 22 Failures and After Sale Services 22 52...
Страница 286: ......
Страница 304: ......
Страница 426: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 498: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 546: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 585: ......