5-40
b) CONTROLLER
Select
2.CONTROLLER
at “SELF DIAGNOSIS” screen, and then press ENT key.
In order to perform the self-diagnosis test, select [ENT], and then press ENT key.
If you do not perform the self-diagnosis test, press
▲
key or
▼
key and select [CANCEL], and
then the cursor is returned back without the test.
When the result of the self-diagnosis test is normal, "OK" is displayed at RESULT:.
- The diagnosis result
The list of the diagnosis result is shown in the following table.
Diagnosis Item
Diagnosis
Result
Defective
Unit
Contents of Failure
Corrective Action
CONTROLLER NG SRAM
CDJ-2983
SRAM error
Replace
CDJ-2983.
NG FROM
CDJ-2983
Flash ROM error
NG
CDJ-2983
Multiple errors in CDJ-2983
c) CONTROLLER LAN
Select
3.CONTROLLER LAN
at “SELF DIAGNOSIS” screen, and then press ENT key.
In order to perform the self-diagnosis test, select [ENT], and then press ENT key.
If you do not perform the self-diagnosis test, press
▲
key or
▼
key and select [CANCEL], and
then the cursor is returned back without the test.
When the result of the self-diagnosis test is normal, "OK" is displayed at RESULT:.
- The diagnosis result
The list of the diagnosis result is shown in the following table.
Diagnosis Item
Diagnosis
Result
Defective
Unit
Contents of Failure
Corrective Action
CONTROLLER
LAN
NG CPU FROM CDJ-2983
CPU internal Flash ROM error
Replace
CDJ-2983.
NG CPU DRAM CDJ-2983
CPU DRAM error
NG CPU RAM
CDJ-2983
CPU RAM error
NG LAN
CDJ-2983
LAN error
NG
CDJ-2983
Multiple errors in CDJ-2983
[LOG DISPLAY OF SELF DIAGNOSIS RESULT]
The past self-diagnosis results are displayed at
4.TRANSPONDER LOG,
,
5.CONTROLLER LOG,
,
and
6.CONTROLLER LAN LOG,
.
When any of the logs are selected, the selected unit’s self-diagnosis results are displayed up to
last 20 results. Log display order is displayed from first to 20
th
sequentially from a new result.
Results and contents according to each diagnostic value are displayed as shown in the following
figure. In the last diagnostic time is displayed.
In addition,”--/-- --:--“ is displayed when time cannot be acquired.
Press
▲
key or
▼
key to change to next page.
C O N T R O L L E R
L O G
1 . C O N T R O L L E R : O K
( 0 0 )
D A T E : 1 1 / 2 4
2 0 : 4 5
2 . C O N T R O L L E R : N G
S R A M
( 0 4 )
▼
D A T E : 1 1 / 2 4
2 0 : 4 5
T R A N S P O N D E R
L O G
1 . T R A N S P O N D E R : N G
C O N T : N G
( 2 5 7 )
I N T G P S :
O K ( 0 )
▼
C O N T R O L L E R
L A N
L O G
1 . C O N T R O L L E R
L A N :
O K ( 0 0 )
D A T E : 1 1 / 2 4
2 0 : 4 5
2 . C O N T R O L L E R
L A N :
N G
S R A M ( 0 4 )
▼
D A T E : 1 1 / 2 4
2 0 : 4 5
Содержание JHS-183
Страница 2: ......
Страница 7: ...v External Views NTE 183 AIS Transponder NCM 983 AIS Controller ...
Страница 8: ...vi Optional equipment NQE 5183 Connection Box NBD 577C Power Supply Unit ...
Страница 12: ...x ...
Страница 16: ...1 4 1 4 Outline Outline Drawing of NTE 183 AIS Transponder Unit mm Mass approx 2 6kg ...
Страница 17: ...1 5 Outline Drawing of NCM 983 AIS Controller Unit mm Mass approx 2 1 kg ...
Страница 18: ...1 6 Outline Drawing of NQE 5183 Connection Box Unit mm Mass approx 2 5 kg ...
Страница 19: ...1 7 Outline Drawing of NBD 577C Power Supply Unit Unit mm Mass approx 5 2 kg ...
Страница 22: ...2 2 ...
Страница 26: ...4 2 ...
Страница 92: ...5 66 ...
Страница 98: ......
Страница 110: ...7 2 ...
Страница 124: ......
Страница 126: ......
Страница 127: ......