5-39
When the result of the self-diagnosis test is normal, "OK" is displayed.
The displayed result of the antenna is not a diagnosis result. It indicates the antenna terminal
during operation.
The diagnosis result of abnormal
The list of the diagnosis result of abnormal is shown in the following table.
Diagnosis
Item
Diagnosis Result Defective
Unit
Contents of Failure
Corrective Action
CONT
NG CPU FROM
CDJ-2483
CPU internal Flash ROM error
CDJ-2483 is defective.
Replace NTE-183.
NG SRAM
CDJ-2483
SRAM error
NG FROM
CDJ-2483
Flash ROM error
NG TX DAC
CDJ-2483
Transmission DA converter error
NG RX1 PORT
CDJ-2483
GMSK receiver CH A input port error
NG RX2 PORT
CDJ-2483
GMSK receiver CH B input port error
NG RX3 PORT
CDJ-2483
DSC reception input port error
NG
CDJ-2483
Multiple errors in CDJ-2483.
INT GPS
NG PPS CONT.
CDJ-2483
Internal GPS unit error
NG SAT.RCV.
CDJ-2483
Internal GPS unit receives signal from
only less than four satellites.
Check the NTE-183
installation conditions.
(*1)
NG
CDJ-2483
Multiple errors
CMN-2183 is
Defective.
Replace NTE-183.
TRX
NG RX1 UNLK
CMN-2183
GMSK receiver CH A synthesizer unlock
NG RX2 UNLK
CMN-2183
GMSK receiver CH B synthesizer unlock
NG RX3 UNLK
CMN-2183
DSC receiver synthesizer unlock
NG TX UNLK
CMN-2183
Transmitter synthesizer unlock
NG RX1 LOOP
CMN-2183
GMSK receiver CH A loop back test error
NG RX2 LOOP
CMN-2183
GMSK receiver CH B loop back test error
NG RX1 RSSI
CMN-2183
GMSK receiver CH A loop back test
Reception level error
NG RX2 RSSI
CMN-2183
GMSK receiver CH B loop back test
Reception level error
NG RX3 RSSI
CMN-2183
DSC receiver loop back test
Reception level error
NG PA
CMN-2183
PA error
NG
CMN-2183
Multiple errors in CMN-2183
PS
NG PS LOW
CBD-2183
Output voltage (9.8 V) error
CBD-2183 is
Defective.
Replace NTE-183.
ANTENNA
INTERNAL
--
The internal antenna terminal is using
EXTERNAL
--
The external antenna terminal is using
(*1): Check that the AIS transponder is not in the shadow of an antenna mast or other antennas.
After the installation conditions of AIS transponder is checked, wait for a while and then
perform the test again.
Caution: If malfunction is found, contact us or our agency as soon as possible.
Содержание JHS-183
Страница 2: ......
Страница 7: ...v External Views NTE 183 AIS Transponder NCM 983 AIS Controller ...
Страница 8: ...vi Optional equipment NQE 5183 Connection Box NBD 577C Power Supply Unit ...
Страница 12: ...x ...
Страница 16: ...1 4 1 4 Outline Outline Drawing of NTE 183 AIS Transponder Unit mm Mass approx 2 6kg ...
Страница 17: ...1 5 Outline Drawing of NCM 983 AIS Controller Unit mm Mass approx 2 1 kg ...
Страница 18: ...1 6 Outline Drawing of NQE 5183 Connection Box Unit mm Mass approx 2 5 kg ...
Страница 19: ...1 7 Outline Drawing of NBD 577C Power Supply Unit Unit mm Mass approx 5 2 kg ...
Страница 22: ...2 2 ...
Страница 26: ...4 2 ...
Страница 92: ...5 66 ...
Страница 98: ......
Страница 110: ...7 2 ...
Страница 124: ......
Страница 126: ......
Страница 127: ......