77
Approved handpieces
Vib85
Weight of handpiece incl. connection cable
0.84 kg
Working lamp in handpiece
4 LEDs, 5000 K
Ambient conditions
+10°C to +40°C
10% to 85% humidity
Noise pressure level
< 70 dB (A)
Approved carbide electrodes,
length 50 mm
Round: Ø 1.0 mm, Ø 1.3 mm, Ø 1.8 mm, Ø 2.3 mm, Ø 3.0 mm,
Ø 4.0 mm
Square: 1.1 mm, 1.6 mm, 2.1 mm
Triangular: 1.95 mm
Approved foot pedal
F85 foot pedal
Manufacturer’s mark and address, type designation, CE marking and serial number are located
on the nameplate on the rear of control units, or on the housing, depending on the handpiece.
The nameplate for the control unit also states the rated voltage (U_rated), the rated current
(I_rated), the rated power (P_rated) and the frequency (F_ultrasonic). It also indicates that the
device is grounded and must not be disposed of in household waste.
Accessories and the spare parts list are available online at www.joke-technology.de.
Safety
Intended use
The system is intended exclusively for applying carbide coatings to metallic surfaces. The
applied carbide layer increases the wear resistance of the coated workpiece without aff ecting
the qualities of the base material.
The unit may only be used with approved components and accessories (see section 4, Technical
specifi cations).
The values specifi ed in the technical specifi cations for the individual components must not be
exceeded when using the system.
Work on and with the unit may only be carried out by qualifi ed, trained and authorised personnel.
The control unit may only be used as described in these operating instructions. Any diff erent or
additional use is considered improper. The manufacturer will not be liable for damage resulting
from improper use.
General safety instructions
To avoid danger to persons and material damage, ALWAYS observe the following safety
instructions:
• Due to its design and use, increased vibrations and noise occur in the vicinity of the hand-
piece. According to the EU Directive 2002/44/EC, a new workplace assessment may have to be
performed.
• Only use the system in technically perfect condition.
• Always place the control unit on a safe, non-slip surface and protect it from contact with
liquids.
• Lay the mains cable so that it is easily accessible and can be disconnected from the power
supply easily.
• When working with the system, always wear safety glasses, gloves and hearing protection.
• Never disconnect the handpiece from the control unit while it is switched on!
• Always switch off the control unit when the system is not in use.
• Do not use the system if display and signal lamps are defective.
• Always make sure that the device’s ventilation slots are free (see also chapter 9).
• Do not leave the system unattended when switched on.
• Switch off and secure the control unit immediately in the event of malfunctions. In the event