Accessories

Table  9: Controller accessories (order separately)

Product code number

Description

IOM Series Controllers

Refer to the 

 Metasys

®

 System Field Equipment Controllers and Related Products Product Bulletin

(LIT-12011042)

 for a complete list of available IOM Series Controllers.

NS Series Sensors

Refer to the 

NS Series Network Sensors Product Bulletin (LIT-12011574) 

for a complete list of

available NS Series Sensors.

Mobile Access Portal (MAP) Gateway

Refer to the 

Mobile Access Portal Gateway Catalog Page

 (LIT-1900869) to identify the

appropriate product for your region.

Note: 

The MAP Gateway serves as a replacement for the BTCVT, which is no longer

available for purchase, but continues to be supported.

TL-CCT-0

Metasys

 Controller Configuration Tool

MS-FCP-0

Metasys

 Equipment Controller Firmware Package Files for CCT

WRZ Series Sensors

Refer to the 

WRZ Series Wireless Room Sensors Product Bulletin (LIT-12011653) for a complete

list of available WRZ Series Sensors.

MS-DIS1710-0

Local Controller Display

Y64T15-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 92 VA, Foot Mount, 72.2 cm (30

in.), Primary Leads and 76.2 cm (30 in.) Secondary Leads, Class 2

Y65A13-0

Transformer, 120 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AS), 20.32 cm (8

in.), Primary Leads and 76.2 cm (30 in.) Secondary Leads, Class 2

Y65T42-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Hub Mount (Y65SP+),

20.32 cm (8 in.), Primary Leads and Secondary Screw Terminals, Class 2

Y65T31-0

Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AR+),

20.32 cm (8 in.), Primary Leads and Secondary Screw Terminals, Class 2

AP-TBK1002-0

2-position Screw Terminal that plugs onto VMA Output Point Spade Lugs

AP-TBK1003-0

3-position Screw Terminal that plugs onto VMA Output Point Spade Lugs

AP-TBK4SA-0

Replacement MS/TP SA Bus Terminal, 4-Position Connector, Brown, Bulk Pack of 10

AP-TBK2PW-0

Replacement Power Terminal, 2-Position Connector, Gray, Bulk Pack of 10

MS-VMAACT-701

VMA Actuator Assembly Gearbox Replacement Kit

AS-CBLTSTAT-0

Cable adapter for connection to 8-pin TE-6700 Series sensors

F-1000-325

Replacement Barbed Fitting for use on VMA1930 for Connecting Tubing, Bulk Pack of 10

F-1000-326

Flexible Tubing Extension with Barbed Fitting for VMA1930, 35.56 cm (14 in.) Length, Bulk

Pack of 20

TL-BRTRP-0

Portable BACnet/IP to MS/TP Router

VMA1930 VAV Controller Installation Guide

18

Содержание VMA1930

Страница 1: ...ence when this equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction m...

Страница 2: ...Table 3 5 Dual Port Fitting 6 Manual Override Button see Mounting for information about using manual override Button 7 Controller Coupler see Mounting for information about using the controller couple...

Страница 3: ...0mA Analog Input Resistive Mode 0 2k ohm RTD 1k NI Johnson Controls 1k PT A998 SI NTC 10k Type L 2 252k Type 2 Binary Input Dry Contact Maintained Mode 3 Binary Output BO 24 VAC Triac 3 Configurable O...

Страница 4: ...ller so that the enclosure walls do not obstruct cover removal or ventilation through the controller Mount the controller so that the power transformer and other devices do not radiate excessive heat...

Страница 5: ...ing an 8 mm 5 16 in wrench or 10 mm 3 8 in 12 point socket Tighten to 10 5 to 11 5 N m 95 to 105 lb in 9 Skip this step if you are installing the VMA1626 model Loop the pneumatic tubing supplied by fi...

Страница 6: ...port Benefits of daisy chained networks are that they require less physical wiring and new devices can be added easily to the network In a star network each VMA1930 controller is connected by Ethernet...

Страница 7: ...inal block is a gray removable 2 terminal plug that fits into a board mounted jack on the upper left of the VMA controller Wire the 24 VAC supply power wires from the transformer to the HOT and COM te...

Страница 8: ...dress See Setting the controller number Also activate the EOL switch if necessary 5 Connect the controller to 24 VAC Class 2 power Note If you are using the VMA1615 1626 1628 1630 controller with the...

Страница 9: ...1k Platinum and A99B Silicon Temperature Sensor Negative Temperature Coefficient NTC Sensor 10K Type L 10K Johnson Controls Type II is equivalent to Type L or 2 252K Type II See Guideline A in Table 4...

Страница 10: ...s Table 4 Cable length guidelines Guideline Wire size Gauge and type Maximum cable length and type Assumptions 1 0 mm 18 AWG stranded copper 457 m 1 500 ft twisted wire 0 8 mm 20 AWG stranded copper 2...

Страница 11: ...Communications COM SA Bus Signal Reference and 15 VDC Common SA BUS 2 2 POWER 15 VDC Supply Power for Devices on the SA Bus 0 6 mm 22 AWG stranded 4 wire 2 twisted pairs shielded cable recommended No...

Страница 12: ...the figures in this section for the applicable termination diagrams Table 6 Termination details Type of field device Type of Input Output Termination diagrams Voltage Input External Source UI Voltage...

Страница 13: ...uator External Source CO 24 VAC Triac Output Switch Low External Source CO Note Applies to CO4 and CO5 Incremental Control to Actuator Switch Low External Source CO Note Applies to CO4 and CO5 Analog...

Страница 14: ...ing the controller Setting the controller number Each controller on a network must have a unique number on the subnet where it resides in order to identify it in the Controller Tool for uploading down...

Страница 15: ...tions on the input and output terminals including the integrated DPT It assumes all Universal Inputs UIs are Nickel temperature sensors All Configurable Outputs COs are treated as Binary Outputs BOs w...

Страница 16: ...uses to trip make sure that the power connections on theVMA1930 are not reversed The most common cause of this problem is when the 24 VAC power supply on the VMA1930 is reversed but not reversed on a...

Страница 17: ...Transformer to be Earth Grounded If this is the case verify that the Earth Ground connection is valid and not shared between multiple pieces of equipment Configurable output analog mode is invalid 0 1...

Страница 18: ...cm 30 in Primary Leads and 76 2 cm 30 in Secondary Leads Class 2 Y65A13 0 Transformer 120 VAC Primary to 24 VAC Secondary 40 VA Foot Mount Y65AS 20 32 cm 8 in Primary Leads and 76 2 cm 30 in Secondar...

Страница 19: ...een 001 and 999 Communications Bus Two Ethernet ports 10 100 Mbps 8 pin RJ 45 connector SA Bus 0 6 mm 22 AWG stranded 4 wire 2 twisted pairs shielded cable recommended from the VMA controller for netw...

Страница 20: ...nced Application Controller B AAC based on the ANSI ASHRAE 135 2016 The performance specifications are nominal and conform to acceptable industry standard For application at conditions beyond these sp...

Отзывы: