Access Control Module
iSTAR Ultra Installation and Configuration Guide
5–15
Figure 5-13:
Wet NO Latch
Wet Wiring for a Magnetic Lock
Magnetic Locks are normally energized so the GND and NC pins are used in this case. Notice
that jumper is in the Wet position, as shown in Figure 5-14 on
.
Figure 5-14:
WET Magnetic Lock
summarizes the function and designation of the ACM LEDs.
Table 5-4:
ACM LED Functions
LED
Function
Comment
DS21
Main Power
- Reader Power - J4
12 Vdc
DS52
Main Power
- LOCK 1 - J2
12 or 24 Vdc
DS54
Main Power
- LOCK 2 - J3
12 or 24 Vdc