Access Control Module
5–14
iSTAR Ultra Installation and Configuration Guide
• Form C
Jumper for each relay to select Wet/Dry and Wet power source
It is convenient to configure a Door with all the components together in one of these sections,
but it is not a requirement. However, all door components must come from the same
controller.
Use the C•CURE Administration Workstation to configure the output as
Normally Energized
for the Fail Safe case.
Dry Relay Wiring
shows DRY relay wiring. Use NO or NC as appropriate. Notice that
jumper is in the Dry position.
Figure 5-12:
Dry Relay Wiring
Wet Relay Wiring
shows Wet wiring for a normal NO Latch. The iSTAR Ultra will
supply 0 to 30 Vdc, depending on the input supply. Current is limited to 0.75 A. Notice that the
GND is used for common, not the C pin. Notice that the jumper is in the Wet position.