PV array
overvolta
ge
Inverter
shutdown
when the
fault
appeared
and will
automaticall
y restart
after it
disappear.
Out put
energy from
array
changes.
Please check
the input
voltage from
array and make
sure this voltage
inside inverter
input voltage
range.
Note: In cloudy
days, morning,
or down, this
situation is not
malfunction.
Dry
alarm
Inverter
shut down
until the
water level
recover or
protection
recover
time is up,
the machine
will restart
automaticall
y.
Water level
of source is
lower than
low-level
water level
sensor,
even lower
than inlet of
pump.
1. Please check
the water level, if
the water level is
ok, please check
if there are air
inside pump.
2. Please check
the position of
water level
sensor.