21
● After inverter operate, if RUN light turn off and other
indicator light turn on, means inverter have fault,detailed
troubleshooting method check out in Appendix.
Manual mode:
● Inverter default setting is Auto mode, if need to manual
turn on off, need to operate through button. Press for
over 3S, inverter turn on, press “ON/OFF” button
together, inverter will be turn off.
Note!
1. During operation, inverter will note down operation mode of last
time power off, If manual turn off, need to turn on manually next
time, if last time is auto turn off, inverter will auto turn on when
power on.
2.
Inverter “ON/OFF” is touch botton, do not press hard!
Note!
1. AC pump motor and inverter phase sequence must be
corresponding, if misconnection, will get no or less water output.
When this happen, should turn off inverter, exchange U V W any
two phases, then power on again.
2. First commission must check phase sequence is correct
connected.
3.
If choose single phase inverter, every time when inverter is
power on again, inverter will be auto winding detection, after
detection successfully, RUN light will turn off for 60S then turn on
again.