28
Condi
tion
code
Condition
Name
Phenome
na
Cause
value
Troubleshoo
ting
Fault
light
on
Short circuit
fault
(Nonrecove
rable)
Inverter
shutdown,
non-recov
er
malfunctio
n. No
automatic
ally
restart,
only if
recharged.
Output wire
short circuit;
inverter
hardware
damage
1. Please
check if there
is short circuit
in output
wires. And if
pump is
damaged.
2. If this
happen
frequently,
please
contact
SUPPLIER.
Motor
detection
fault
Inverter
shutdown,
non-recov
er
malfunctio
n. No
automatic
ally
restart,
only if
recharged.
Inverter one
phase or
two phase
is not
proper
connected
with motor,
or motor
damage.
Please check
if three phase
output is
properly
connected,
motor is
damaged or
not.
Initialization
fault
Inverter
shutdown,
non-recov
er
malfunctio
n. No
Inverter
inside
storage
reading
fault;
Inverter
Power on
again to
restart, if
restart still
show this
fault, means