27
IPM FO
fault
Inverter
shutdown
and will
restart
automaticall
y after the
fault
disappears.
Pump
damage
cause
output short
circuit;
Inverter
hardware
damage.
Check if pump is
damaged, if
pump is okey,
then inverter
inside hardware
damage if restart
failure.
IPM over
heat
Inverter
shutdown
and will
restart
automaticall
y after the
fault
disappears.
Inverter
radiator
over heat;
hardware
damage.
1. If external
temperature is
too high to
cause inverter
over heat, when
temperature
goes down,
inverter will
restart;
2. If cannot
restart for a long
time, consider
inverter
hardware
damage.
Note: in Summer
with high
temperature,
this situation is
not malfunction.
Malfunction and troubleshooting: