65
State 109
Dry alarm
Inverter
shut
down until the
water
level
recover
or
protection
recover time is
up,
the
machine
will
restart
automatically.
Water level
of source is
lower than
low-level
water level
sensor,
even lower
than inlet of
pump.
1. Please check the
water level, if the
water level is ok,
please check if there
are air inside pump.
2. Please check the
position
of
water
level sensor.
State 110
Weak
sunshine
Inverter
shutdown.
When
malfunction
disappear,
inverter
can
restart
automatic.
Array
output low.
Usually appears in
early morning, dusk
and
cloudy
days.
This situation is aim
to protect the motor
of
pump
and
lengthen the lifetime.
State 114
Overflow
alarm
Inverter
shut
down until the
water
level
recover
or
protection
recover time is
up,
the
machine
will
restart
automatically.
Water level
in container
higher than
high-end
level
sensor.
If
this
situation
appears more than
once, please check
onsite and set the
water level sensor at
a proper height.