37
Notice
!
Electrostatic discharging will cause damage to the inner components of inverter. We
should carry out the antistatic measure before disassembling and assembling.
6.8.2 Disassembling of Connector
Due to maintenance and other reasons, it is necessary to disassemble the inverter
cover plate. In order to ensure the sealing performance of the product, please follow
the following methods:
1.When removing the inverter, use the phillips screwdriver first and remove the ground
screw on the right side of the inverter case;Then use no.5 inner hexagon wrench and
unscrew the cover plate fixing screw in turn.There is a gasket under the screw. Pay
attention to prevent the gasket from falling off when unscrewing.
2.When installing, first use a phillips screwdriver, lock the ground screw on the right
side of the inverter case, and then screw the organic cover screw into the screw
hole;Use the 5# inner hexagon wrench with a torque of 1.8± 0.2n ·M. Tighten the
diagonal screws first and then the other screws in turn.
Figure6-12 Inverter disassembly reference drawing