55
Pacc
During economic mode, when the solar power is lower
than the access power, the grid access ensures the
operation of the inverter with the maximum power.(Thi s
parameter setting is recommended to be about 45% of
the load pump power, with the minimum change power
of 100W.)
Pexit
During economic mode, when the solar power is higher
than the access power, the power grid exit ensures that
the inverter only use solar energy.(This parameter
setting is recommended to be about 75% of the load
pump power, with the minimum power change of
100W.)
Poffgrid
Set the grid input power when the grid is completely
off.(This parameter setting is recommended to be about
90% of the load pump power, with the minimum change
power of 100W.)
S_Out
Set inverter output type selection, "0" means
three-phase pump load, "1" means single-phase pump
load.
ESC
Return to the previous menu.