When doing solar water pump system configuration, it is necessary to ensure
that the Vmp of the PV array is basically equal to or close to the AC rectifier
voltage. That is, Vmp
≈
1.414 * U wire (use a multimeter to measure the
voltage between any two phases in three-phase electricity, that is, U wire), for
example, Vmp of PV Module is 30V, and 18pcs in series, the Vmp of PV string
is 30 * 18 = 540V
≈
1.414 * 380 = 537.3v.
If the configuration of PV array is not appropriate, when PV energy and AC
energy are connected at the same time, the utilization rate of PV energy shall
be poor.