70
disappears.
inverter output.
2. Make sure that the pump
is working in the well range
of head and flow.
3. Please refer to “
8.3.4.3
”
to raise the figure of Imotor.
Fault106
Inverter shutdown
and
will
restart
automatically after
malfunction
disappears.
DC
input
voltage higher
than maximum
input voltage of
inverter.
Please
check
maximum
output voltage of array and
make sure this voltage is
below
inverter
maximum
input voltage.
Fault107
Inverter shutdown
and
will
restart
automatically after
the
fault
disappears.
Input current of
inverter higher
than
rated
maximum
value.
If
this
happen,
please
contact Our company.
Fault108
Inverter shutdown
and
will
restart
automatically after
the
fault
disappears.
1. Power
capacity of
pump motor is
higher than
rated output.
2. Pump motor
locked-rotor,
or damaged.
3.Pipe system
design is not
reasonable
1. Please
inspect
whether
pump motor is normal.
2. Please
inspect
whether
pipeline
system
is
in
accordance with water pump
or not.
3. If this happen frequently,
please contact Our company.
Содержание JNP1K1L-G
Страница 1: ...I Solar Pumping Inverter 用户手册 User Manual JNP1K1L G JNP1K5L G JNP2K2L G JNP2K2L G V3 EN V3 0 ...
Страница 55: ...47 Figure8 2 LCD diagram 1 ...
Страница 86: ...78 ...