59
Load
For selection of load. This figure differs by different
pump.
D-Mode
For choose the dry out protection mode. W hen
water sensor is applied, dry protection mode should
be set to detect dry protection. Default is
“DETECT”.
OF-F
For choose over flow warning function. Default is no
overflow warning. If you want to use this function,
please set to “on”. Default is “OFF”.
OF-Time
For choose over flow warning function. Over flow
recovery time, after the warning of over flow and
inverter shut down, the duration from shut down to
restart. Default value is 30. Default duration is 30
minutes.
M-Mode
If water output is abnormal, and caused by reversed
motor phase sequence, you can try to reset this
model from “REV” to “FW D”. Default is “FW D”.
V-Hys
AC input frequency limit change voltage
T-Delay
AC input frequency limit change time
ESC
Return to the previous menu.
Note
!
When users choose solar pumping system, the parameters in the "DSP
parameters setting" menu have been already set out, and these parameters
can not be easily changed.