![Jetter JVM-507B - HMI Скачать руководство пользователя страница 50](http://html2.mh-extra.com/html/jetter/jvm-507b-hmi/jvm-507b-hmi_user-manual_3864918050.webp)
50
Jetter AG
5 Mounting and installation of the JVM-507B
Setting the IP address during runtime
The IP interface is initialized by the settings in the configuration memory
during the boot process.
The following volatile settings can also be changed via registers:
IP address
Subnet mask
IP address of default gateway
The settings made during runtime do not overwrite the parameters in the
configuration memory. At de-energizing the device, your settings will be lost.
Register
Description
104531
IP address of the HMI
104532
Subnet mask
104533
IP address of default gateway
To set the IP address and the subnet mask, proceed as follows:
Step
Action
1
Enter the desired IP address into R 104531.
2
Enter the desired subnet mask into R 104532.
3
Enter the desired IP address of the default gateway into R 104533.
Result:
The settings are completed. Communication is possible again.
The configuration memory
(see page 46)
Introduction
Important note
Registers - Overview
Setting IP addresses and
subnet mask
Related topics
Содержание JVM-507B - HMI
Страница 1: ...User Manual JVM 507B HMI 60881526 We automate your success...
Страница 8: ......
Страница 12: ......
Страница 52: ......
Страница 70: ...70 Jetter AG 6 Initial commissioning Initial commissioning in JetViewSoft see page 58 Related topics...
Страница 78: ......
Страница 88: ......
Страница 99: ...Jetter AG 99 JVM 507B Programming If Merker1 Then Inc Status_LEDs Delay T 100ms End_If End_Loop End_Task...
Страница 106: ......
Страница 128: ......
Страница 146: ...146 Jetter AG Appendix The JVM 507B is intended for installation in the driver s cabin Installation location...
Страница 151: ......