![Jetter JVM-507B - HMI Скачать руководство пользователя страница 130](http://html2.mh-extra.com/html/jetter/jvm-507b-hmi/jvm-507b-hmi_user-manual_3864918130.webp)
130
Jetter AG
11 Quick reference - JVM-507B
102917
Year
Buffer access
102920
Milliseconds
102921
Seconds
102922
Minutes
102923
Hours
102924
Day of the week (0 = Sunday)
102925
Day
102926
Month
102927
Year
102928
Read/write trigger
Ethernet
IP
104531
Current IP address (rw - temporary)
104532
Current subnet mask (rw - temporary)
104533
Current default gateway (rw - temporary)
CAN
106000
Baud rate CAN 1
106001
Node-ID CAN 1
106100
Baud rate CAN 2
106101
Node-ID CAN 2
microSDHC card
107000
Bit 0 = 1: Card installed
Bit 1 = 1: Card is ready
107001
1 = Card is write-protected
(only valid if R 107000 = 3)
107002
Size in MB (float)
System information
108500 ...
108509
JetVM-DII version string
108510 ...
108519
Version string of the host application
108520 ...
108529
File name of the host application
108530 ...
108539
OS version (string)
108570
CPU type
108571
Number of CPUs
108573
Physical RAM
108574
Free physical RAM
108575
Memory utilization (in %)
108581
Screen width (in pixels)
108582
Screen height (in pixels)
108590
HID version
USB flash drive
109000
Bit 0 = 1: Data medium is available
Bit 1 = 1: Data medium is ready
109002
Size in MBytes
General system registers
200000
OS version (major * 100 + minor)
200001
Application program is running (bit 0 = 1)
200008
Error register (identical with 210004)
Bit 8:
Illegal jump
Bit 9:
Illegal call
Bit 10:
Illegal index
Bit 11:
Illegal opcode
Bit 12:
Division by 0
Bit 13:
Stack overflow
Bit 14:
Stack underflow
Bit 15:
Illegal stack
Bit 16:
Error when loading the application program
Bit 24:
Timeout - Cycle time
Bit 25:
Timeout - Task lock
Bit 31:
Unknown error
200168
Bootloader version (IP format)
200169
OS version (IP format)
201000
Runtime register in milliseconds (rw)
201001
Runtime register in seconds (rw)
201002
Runtime register in R 201003
Units (rw)
201003
* 10 ms units for R 201002 (rw)
201004
Runtime register in milliseconds (ro)
202930
Web status (bit-coded)
Bit 0 = 1:
FTP server available
Bit 1 = 1:
HTTP server available
Bit 2 = 1:
E-mail available
Bit 3 = 1:
Data file function available
Bit 4 = 1:
Modbus/TCP has been licensed
Bit 5 = 1:
Modbus/TCP available
Bit 6 = 1:
Ethernet/IP available
202960
Password for system command register (0x424f6f74)
202961
System command register
202980
Error history: Number of entries
202981
Error history: Index
202982
Error history: Entry
203000
Interface monitoring: JetIP
203005
Interface monitoring: Debug server
203100 ...
203107
32-bit overlaying - Flag 0 ... 255
203108 ...
203123
16-bit overlaying - Flag 0 ... 255
203124 ...
203131
32-bit overlaying - Flag 2048 ... 2303
203132 ...
203147
16-bit overlaying - Flag 2048 ... 2303
209700
System logger: Global enable
209701 ...
209739
Enabling system components
Application program
210000
Application program is running (bit 0 = 1)
210001
JetVM version
Содержание JVM-507B - HMI
Страница 1: ...User Manual JVM 507B HMI 60881526 We automate your success...
Страница 8: ......
Страница 12: ......
Страница 52: ......
Страница 70: ...70 Jetter AG 6 Initial commissioning Initial commissioning in JetViewSoft see page 58 Related topics...
Страница 78: ......
Страница 88: ......
Страница 99: ...Jetter AG 99 JVM 507B Programming If Merker1 Then Inc Status_LEDs Delay T 100ms End_If End_Loop End_Task...
Страница 106: ......
Страница 128: ......
Страница 146: ...146 Jetter AG Appendix The JVM 507B is intended for installation in the driver s cabin Installation location...
Страница 151: ......