210004
Error register (bit-coded)
Bit 8:
Illegal jump
Bit 9:
Illegal call
Bit 10:
Illegal index
Bit 11:
Illegal opcode
Bit 12:
Division by 0
Bit 13:
Stack overflow
Bit 14:
Stack underflow
Bit 15:
Illegal stack
Bit 16:
Error when loading the application program
Bit 24:
Timeout - cycle time
Bit 25:
Timeout - task lock
Bit 31:
Unknown error
210006
Highest task number
210007
Minimum program cycle time
210008
Maximum program cycle time
210009
Current program cycle time
210011
Current task number
210050
Current program position within an execution unit
210051
ID of the execution unit being processed
210056
Desired total cycle time in µs
210057
Calculated total cycle time in µs
210058
Maximum time slice per task in µs
210060
Task ID (for R210061)
210061
Priority for task [R210060]
210063
Length of scheduler table
210064
Index in scheduler table
210065
Task ID in scheduler table
210070
Task ID (for R210071)
210071
Timer number (0 ... 31)
210072
Manual triggering of a timer event (bit-coded)
210073
End of cyclic task (task ID)
210074
Command for cyclic tasks
210075
Number of timers
210076
Timer number (for R210077)
210077
Timer value in milliseconds
210100 ...
210199
Task state
210400 ...
210499
Task - Program address
210600
Task ID of a cyclical task (for R210601)
210601
Processing time of a cyclical task in per mil figure
210609
Task lock timeout in ms
-1: Monitoring disabled
210610
Timeout (bit-coded)
Bit 0 -> Timer 0, etc.
Networking via JetIP
230000
JetIP/TCP server: Number of open connections
230001
JetIP/TCP server: Mode
230002
JetIP/TCP server: Time
232708
Timeout in milliseconds
232709
Response time in milliseconds
232710
Amount of network errors
232711
Error code of last access
0 = No error
1 = Timeout
3 = Error message of the remote station
5 = Invalid network address
6 = Invalid amount of registers
7 = Invalid interface number
232717
Max. number of retries
232718
Number of retries
Modbus/TCP
272702
Register offset
272704
Input offset
272705
Output offset
278000 ...
278999
16-bit I/O registers overlaid by virtual I/Os 20001 ...
36000
File system/data file function
312977
Status of file operation
312978
Task ID
User-programmable IP interface
Reading out the connection list
350000
Last result (-1 = no connection selected)
350001
1 = Client; 2 = Server
350002
1 = UDP; 2 = TCP
350003
IP address
350004
Port number
350005
Connection state
350006
Number of sent bytes
350007
Number of received bytes
Application registers
1000000 ...
1005999
32-bit integer (non-volatile)
CAN-PRIM registers
200010500
CAN-PRIM status
200010501
CAN-PRIM command register
200010502
Message box number
200010503
FIFO buffer occupancy
200010504
FIFO data
200010506
Global receiving mask
200010507
Global receive ID
200010510
Box status register
200010511
Box configuration register
200010512
CAN ID
200010513
Number of data bytes
200010514
...
200010521
Data bytes
Display
Function keys
361000 ...
361011
Bit-coded map of function keys
e.g. bit 0: 1 = Key 1 is pressed
Ignition (IGN)
361100
Bit 0:
0 = Ignition ON
1 = Ignition OFF
Display
Содержание JVM-507B - HMI
Страница 1: ...User Manual JVM 507B HMI 60881526 We automate your success...
Страница 8: ......
Страница 12: ......
Страница 52: ......
Страница 70: ...70 Jetter AG 6 Initial commissioning Initial commissioning in JetViewSoft see page 58 Related topics...
Страница 78: ......
Страница 88: ......
Страница 99: ...Jetter AG 99 JVM 507B Programming If Merker1 Then Inc Status_LEDs Delay T 100ms End_If End_Loop End_Task...
Страница 106: ......
Страница 128: ......
Страница 146: ...146 Jetter AG Appendix The JVM 507B is intended for installation in the driver s cabin Installation location...
Страница 151: ......