Installation & Operation manual of Jetmaster UK clean burn range
Page 6
Revision 10/02/2010
•
Roll of Insulation
•
Door operating tool
•
Tin of Paint
•
Installation & Operating Instructions
•
Guarantee card
CHIMNEY AND FLUES
The flue and chimney must be inspected before installation to ensure that it is suitable for the appliance being
fitted.
Soundness of Flue
The flue must be sound and free from cracks and obstructions.
All flues should be swept clean prior to installation and inspected for soundness and freedom from blockages.
Any flue cowl must comply with the test requirements for use with burning solid mineral fuels.
Flue Size / Dimensions
Weather the chimney is old or is newly built, its dimensions must be adequate to support the size of fire to be
installed. The larger the fire, the greater the size of flue and the taller the chimney required. When specifying flue
cowl, ensure that the important internal dimensions are stated.
The flue must not be used for any other appliance or application.
Use of Existing Chimneys
These must be swept and inspected for dimensions and soundness before starting to install the fire. Existing flue
cowl should be inspected and replaced if required.
Termination
It is important to terminate the top of the flue in such a way that it will allow free passage of combustion products to
the atmosphere without being subjected to turbulent air or high pressure zones that could cause a downdraught.
Building regulations stipulate minimum clearance above windows and ventilation openings.