Installation & Operation manual of Jetmaster UK clean burn range
Page 7
Revision 10/02/2010
Flue Outlet
Flow from the outlet must be totally free from any obstruction.
Bends
The ideal flue is straight and vertical. New chimneys must not deviate more than 45º from the vertical, but it is
desirable that the deviations do not exceed 30º. Bends greater than 30º are not allowed in pre-fabricated metal
chimneys. In older chimneys bends exceeding 45º may be found and will degrade flue performance.
Sweeping
The chimney can be swept through the fire. The fire is provided with removable V baffles to facilitate chimney
sweeping and for the removal of soot from the unit. The fire must be installed in such a way that this can be carried
out.
OUTER BOX INSTALLATION
CAVITY RECOMMENDED
MODEL
WIDTH
LENGTH
HEIGHT
18I
457
355
554
60I
647
355
593
70I
647
355
593
All dimensions in mm