Installation & Operation manual of Jetmaster UK clean burn range
Page 8
Revision 10/02/2010
Site Preparation for Fitting
Builders Opening
If installing the fire in an existing fireplace, first remove all loose material from the recess and measure the opening
and recess to ensure that the Jetmaster outer firebox will fit. The opening must be high and wide enough to allow
the outer firebox to be pushed into position. Allow extra height if connecting directly to the existing flue to make the
connection.
The recess must be large enough to provide a clearance around the sides and back of the outer firebox to allow the
insulation to be fitted. Cut away or build up to achieve the desired dimensions.
Do not remove any structural lintels without first seeking expert advice. Often identification and location of the lintel
can be found by removing some surface plaster above the opening that is to be altered.
Alternative methods of creating the required recess size are shown in the diagram below.
Where the recess is to be newly built, form the recess to give a clearance around the sides and back of the outer
firebox to accommodate the insulation.
The fire
must
be directly connected to the flue system. With an existing flue, check that a sealed flue connection
can be achieved between the fire adaptor and the flue
The fire surround should be flat around the sealing area of the fire. Check that the hearth, or new plinth where this
is constructed, is horizontal and parallel to the finished fire lines.
Содержание INSET STOVE MKIII 60i
Страница 1: ......